Dental Grade Resin
● Burning clear
● Low contraction percentage
● Low smell, non toxic
Description
Technical Parameters
Dental grade resin is a high-performance material specifically formulated for use in dental applications, such as restorative procedures, orthodontics, and prosthetics. This resin is designed to meet the stringent standards of dental professionals, offering precision, durability, and aesthetic qualities for a wide range of dental treatments.

1. Dental Casting Resin
Low odor and non-toxic: Ensures a safer working environment.
Low shrinkage: Maintains accurate printing with minimal dimensional changes.
High molding precision: Ideal for dental teaching and applications, offering precise details and smooth surfaces.
2. Tough Resin
High model accuracy: Low shrinkage and stable printing size ensure high printing precision.
Fine texture: Models exhibit smooth surfaces and clear three-dimensional details.
3. Black Resin
High curing speed: XINSHAN resin accelerates printing speed and reduces curing time without compromising the strength of the molded parts. This optimizes the printing efficiency of LCD machines.
4. Strong and Balanced
Excellent strength and flexibility: The finished model demonstrates strong impact resistance and balanced properties, ensuring durability without compromising on detail accuracy. Materials that are too hard risk shattering upon impact, while overly flexible materials may cause deformation during printing, affecting both molding accuracy and aesthetics.
5. Bright and Pure Colors
Vibrant and full colors: Meets the international G7 standard, delivering bright and true colors for enhanced visual appeal and quality.
Application of resin dental




Restorative Dentistry: Ideal for dental crowns, inlays, onlays, and bridges.
Orthodontics: Used in the creation of clear aligners, retainers, and other orthodontic appliances.
Prosthetics: Enables the production of dentures, partials, and other dental prosthetic devices.
Dental Models: Perfect for creating detailed and accurate models for treatment planning and custom dental solutions.
Castable Resin Inspection Certificates

Picture Show


Precautions:
Shake well before use to ensure thorough mixing and maintain uniformity throughout the resin. Avoid using the resin in areas with direct sunlight exposure, as ultraviolet rays can cause premature curing.
Do not ingest the resin and keep it out of reach of children. Always wear gloves to prevent direct skin contact, and ensure the working area is well-ventilated indoors to minimize exposure risks.
Avoid contact with eyes. If accidental exposure occurs, rinse with plenty of water immediately and seek medical attention if any discomfort persists.
Clean printed resin models using high-concentration alcohol (above 95% is recommended; the higher the concentration, the better) for about 30 seconds.
Never return used resin to the unused supply, and avoid leaving resin in the tray for extended periods without use.
For long-term storage, place the resin in a sealed container and protect it with a plastic wrap to prevent contamination and preserve its printing quality.
Storage Method:
Store in a cool, dark place at room temperature. Exposure to sunlight can cause the photosensitive resin to cure prematurely due to ultraviolet rays. It is important to avoid UV light under regular lighting conditions to maintain the resin's integrity during storage.
The recommended storage temperature is between 15°C to 35°C. Lower temperatures can increase resin viscosity, making it more difficult to use, while higher temperatures are not advisable as they may degrade the resin quality.
Keep the container sealed to prevent excessive dust or moisture from contaminating the resin, which could negatively affect print quality. Proper sealing ensures the resin remains usable over time, maintaining its optimal performance characteristics.
FAQ
1. What are the main features of Dental Casting Resin?
Dental Casting Resin offers low odor, non-toxicity, low shrinkage, accurate printing, and high molding precision, making it ideal for dental teaching and application.
2. How does Tough Resin compare to other resins?
Tough Resin stands out with its high model accuracy, low shrinkage, and stable printing size, providing fine textures and smooth surfaces that highlight three-dimensional details.
3. What are the advantages of using Black Resin?
Black Resin offers high curing speed, which speeds up the printing process and reduces curing time while maintaining the strength of the molded parts, enhancing the efficiency of LCD machines.
4. Why is balance important in the properties of Black Resin?
Balance in Black Resin is crucial because it provides both strong impact resistance and flexibility, avoiding issues such as shattering or deformation that can compromise printing accuracy and aesthetics.
5. How do bright and pure colors benefit the quality of printed models?
Bright and pure colors, in line with the international G7 standard, ensure vibrant and full visuals for printed models, enhancing their appeal and meeting high standards of quality and color fidelity.
6. Can these resins be safely used in dental applications?
Yes, all these resins-Dental Casting Resin, Tough Resin, and Black Resin-are formulated to be low in odor, non-toxic, and safe for dental applications, ensuring both functional and aesthetic requirements are met for dental models and prosthetics.
Contact Us:xslightings@xslightings.com
Hot Tags: dental grade resin, China, suppliers, manufacturers, factory, custom, wholesale
Technical Data:
Liquid Properties
| Appearance | Liquid resin | |
| Viscosity @25°C,cps | 125 ±25 | |
| Density @25°C,g/cm³ | 1.05 -1.13 | |
| Alcohol solubility | Soluble in alcohol | |
| Water solubility | Slightly soluble in water | |
| Color | Green | |
Light-cured Solid Properties:
| Item | Post-cured | Method |
| Hardness,D | 81 | Scale D |
| Tensile Strength,MPa | 42-62 | ASTM D638 |
| Young's Modulus,MPa | 2545±100 | ASTM D638 |
| Elongation at Break,% | 15±5 | ASTM D638 |
| Flexural Strength,MPa | 53±5 | ASTM D790 |
| Flexural Modulus,MPa | 2425±100 | ASTM D790 |
| 1ZOD Impact Strength,J/m | 46±3 | ASTM D256 |
| HDT,°C | 75 | ASTM D-648 |
| Volume shrinkage,% | 1.88-2.45 | |
| Linear shrinkage,% | 0.8-1.00 | |
| Thermal expansion | 95*E-6 | |
| Glass transition temp,°C | 110 |